Icons Guide
STERIONIZER
Generating sterionizer
ions that leads to
electrochemical reaction
that deactivates bacteria,
viruses and allergenic
particles. Creating and
brings a natural air quality
to the living environment.
ACTIVE CARBON
FILTER
Effectively cleans the air
from air-born particles
down to 0.01µ avoid
cigarettes smoke, house
cooking smoke, pollen,
mold, spores
and bacteria.
NANO
PHOTOCATALYTIC
FILTER
Oxidize and degrade
organic contaminants. It
can effectively eliminate
99.9% of bacteria and
collect dust effectively.
ELECTROSTATIC
FILTER - ANTIBACTERIA
Anti Bacteria Remove in
high efficient small particles
from the air and purify the
air from bacteria.
AUTO CLEAN/DRY
Avoid bacteria and mildew
growing by keeping the
heat exchanger dry after
cooling operation.
FRESH AIR
Refresh the room by
supplying fresh air from
outside.
FLEXY MATCH
Outdoor unit can match
several type of indoor units.
Indoor unit can match
single split or multisplit
outdoor units.
A/A CLASS
EFFICIENCY
High efficiency and energy
saving product.
DC INVERTER
Compressor with high
efficiency DC motor.
1 W STANDBY POWER
Minimize the waste of
energy once unit is in a
standby mode.
LOW VOLTAGE
STARTUP
Design to start up the
system even once power
supply is not stabilized.
LOW TEMPERATURE
STARTUP
Start up the system even
once outside temperature
is very low as -15°C.
R410A FLUID
Refrigerant fluid R410A.
R32 FLUID
Refrigerant fluid R32.
VAV COMPATIBILITY
Automatic air volume
and system control per
zone related to the gap
between actual room
temperature and set up
temperature.
ELECTRONIC
EXPANSION VALVE
Precise refrigerant flow
control, optimize the
performance and protect
the compressor.
REFRIGERANT
LEAKAGE DETECT
Indicate in indoor side once
leakage is detected and
stop the system to protect
the compressor.
FILTER CLEAN
INDICATION
Sign to check and
clean the air filter.
I FEEL
Precise tempereture
control around dedicated
area by using remote
control temperature sensor.
WIDE ANGLE
LOUVER
Better cooling and heating
affect by extending the air
distribution in the room in a
wide angle.
MOTORIZED 4D
AIRFLOW
Excellent cooling and
heating affect by swing the
air up and down, left and
right automatically.
MULTIFLOW 360°
Most comfort air
distribution system by
supply air in four direction
in 360° and motorized
louver control.
SLEEP MODE
Adjusting the room
temperature along the
night follow human
sleep behaviour.
SUPER QUIET
Advanced design for
low sound level.
HOT KEEP
Control the fan operation
to avoid drafting of cold air
during start operating in
heating.
AIR QUALITY/CLEAN
COMFORT FUNCTIONS
STANDARD OPTION
TECHNOLOGY
1
W
Low
Low
FLEXY
MATCH
AUTO
CLASS
Seitenansicht 19